TMS
Minigage: Short Standoff Non-Contact Thickness Gage
Up to 6 inch standoff
2 (two) 18mm diameter gage heads
per measurement
Thickness Minigage
The thickness MINIGAGE is similar to the TMS-5000 except for
the sensor, sensor housing, sensor alignment, air service and
price.
Air service-Employs an internal fan/filter within the sensor
housing, drawing power from the MINIGAGE controller,
eliminating the need for an external fan, filter and steam
hose used in the 5000 series. The MINIGAGE should not be used
in environments where there is moderate to heavy airborne
contamination.
Thickness Minigage
Specification
PERFORMANCE
Accuracy:
+/-0.001” or +/-0.1% of the distance from the transducer to
the target surface, whichever is greater
Repeatability:
+/-0.05% of the distance from the transducer to the target
Inspection Rate:
Variable to 58 measurements per second
Operating Range:
0.2” - 23.999” or 5mm - 609mm (Transducer to target)
Off-Axis Alignment:
+/- 2.5 to 5 degrees depending on target size, material and
range
ELECTRICAL
Input Power:
100 VAC, 50/60 Hz
120 VAC, 60 Hz
230 VAC, 50 Hz
Maximum Power Consumption: 36 watts
Standard Interfaces: Full duplex asynchronous RS-232C, 3-wire
or RS-422A, 5-wire
Communications interface:
Baud Settings: 300, 600, 1200, 2400, 4800, 9600, 19200, none
Word Length: 8 bit; 7 ASCII + 1 Parity Bit
Parity: unused
Stop Bit: 1 stop bit
Line Status: disable
16 bit parallel binary output, TTL Compatible 3mA Source, 20mA
Sink
Optional Interface:
Analog: 0-10 VDC or 4-20mA (up to 2500 Ohm load for 4-20mA)
Selectable analog span: 00.00” to 23.9999” or 0mm to 609mm in
incremental steps of voltage or current within span: 4096
steps
MECHANICAL/ENVIRONMENTAL
Dimensions and Weight:
Controller: 12”H x 12”W x 7.5”D 25 lbs Enclosure NEMA 13
Rated
Air Hood, Transducer and Internal Fan: 2.5”H x 2.5”W x 4.5”L
11 ozs
Temperature: Operating -20 to +50 C
Noise Immunity:
Acoustic: Filtered to eliminate noise spectrum of common
industrial environments
Electrical: Shielded for RF/EMI
Humidity: 95% maximum Non-condensing
Transducer to Controller Separation:
Standard: 10’-30’ Optional: 500’
PROGRAMMABLE TRANSDUCER CONTROLLER
Display: 5 digit LED display on controller
Programming: 2 momentary push button switches on controller
provide local programming of parameters. Controller can also
be programmed remotely via the RS-232C, RS-422A interface
Signal Compensation: Continuous automatic calibration for
temperature changes
Sample Averaging: Programmable from 1 to 4095 samples per
measurement
Amplitude Filter: Programmable to filter measurements from
vibrating or poorly aligned targets
Run Mode: Programmable for free running or sample on command
by switch or contact closure
Relay Configuration: Programmable relay closure in or out of
limit set points. Electromechanical SPDT rated 2A maximum, 60
VDC
Relay Thickness Limit Set Points: Programmable high and low
relay limit set points for selectable closure, normally-in or
normally-out of limits in 0.01 inch increments
Delay to Relay Closure: Programmable relay delay from 0.002 to
65 seconds in 0.002 second increments
Relay Closure Interval: Programmable relay closure interval
from 0.002 to 65 seconds in 0.002 second increments.