DMS
5000: Long Standoff Non-Contact Distance Gage
Up
to 24 inch standoff
1 (one) 30mm diameter gage head per measurement
The DMS 5000 is a non-contacting, ultrasonic precision
distance measurement system capable of accuracies of 0.001" or
better. It is intended for hostile environments as a stand
alone system or with a computer or PLC. Options are available
for analog output, automatic recalibration to a reference
surface, Measuremate software and
numerous software options. Options allow the gage to be used
in hybrid distance applications including, runout,
straightness, fill level, blind hole depth, counting,
thickness, flatness, missing bearing detection, piston height,
etc. The gage comes complete with controller, mounting
fixturing, air service, filters, electronic alignment and
cables.
Like the TMS family of products, the measurements taken by the
DMS series are not affected by surface variations such as
color, texture and reflectivity, electronic or mechanical
noise, humidity, lighting, water vapor, dust, or temperature.
The DMS products are non-contact, air-coupled ultrasonic
distance measurement systems designed for use in industrial
environments. The DMS product family can measure to a distance
of 23.9999 inches from the material surface.
Any surface, liquid or solid, can be measured, on line, to an
accuracy of better than one-thousandth of an inch.
Applications include inspecting piston engines for missing
connecting rod bearing inserts, measuring the piston deck
height in diesel engines, precision fill level, depth of a
blind hole, flatness, bottle cap security, etc.
PERFORMANCE
Accuracy: +/-0.00025" or +/-0.025% of the distance from
the transducer to the target surface, whichever is greater,
for distances up to 1.5", +/-0.033% from 1.5" to 4" and
+/-0.05% thereafter.
Repeatability: +/-0.00025" or +/-0.025% of the distance
from the transducer to the target.
Inspection Rate: Variable to 125 measurements per
second.
Operating Range: 0.2" - 23.999" or 5mm - 609mm (Transducer to
target).
Off-Axis Alignment: +/- 2.5 to 5 degrees depending on target
size, material and range.
ELECTRICAL
Input Power:
100 VAC, 50/60 Hz
120 VAC, 60 Hz
230 VAC, 50 Hz
Maximum Power Consumption: 35 watts
Standard Interfaces: Full duplex asynchronous RS-232C, 3-wire
or RS-422A, 5-wire communications interface
Baud Settings: 300, 600, 1200, 2400, 4800, 9600, 19200, none
Word Length: 8 bit; 7 ASCII + 1 Parity Bit
Parity: unused
Stop Bit: 1 stop bit
Line Status: disable
16 bit parallel binary output, TTL Compatible 3mA Source, 20mA
Sink
Optional Interface:
Analog: 0-10 VDC or 4-20mA (up to 2500 Ohm load for 4-20mA)
Selectable analog span: 00.00" to 23.9999" or 0mm to 609mm in
incremental steps of voltage or current within span: 4096
steps
MECHANICAL/ENVIRONMENTAL
Dimensions and Weight:
Transducer: 5"H x 1.5"D .33lbs
Controller: 12"H x 4.5"W x 4.0"D, 25 lbs Enclosure NEMA 13
Rated
Industrial Air Hood: 11"H x 4.5"W x 4.0"D 5 lbs
Air Fan/Filter: 110V, 15"H x 14"W x 15"D 20 lbs
Temperature: Operating -20 to +50 C
Noise Immunity:
Acoustic: Filtered to eliminate noise spectrum of common
industrial environments
Electrical: Shielded for RF/EMI
Humidity: 95% maximum Non-condensing
Transducer to Controller Separation:
Standard: 10'-30' Optional: 500'
PROGRAMMABLE TRANSDUCER CONTROLLER
Display: 5 digit LED display on controller
Programming: 2 momentary push button switches on controller
provide local programming of parameters. Controller can also
be programmed remotely via the RS-232C, RS-422A interface
Signal Compensation: Continuous automatic calibration for
temperature changes
Sample Averaging: Programmable from 1 to 4095 samples per
measurement
Amplitude Filter: Programmable to filter measurements from
vibrating or poorly aligned targets
Run Mode: Programmable for free running or sample on command
by switch or contact closure
Relay Configuration: Programmable relay closure in or out of
limit set points. Electromechanical SPDT rated 2A maximum, 60
VDC
Relay Thickness Limit Set Points: Programmable high and low
relay limit set points for selectable closure, normally-in or
normally-out of limits in 0.01 inch increments
Delay to Relay Closure: Programmable relay delay from 0.002 to
65 seconds in 0.002 second increments
Relay Closure Interval: Programmable relay closure interval
from 0.002 to 65 seconds in 0.002 second increments
|
|


|